Monday, July 27, 2020

Industrial Electronics M6 connector


Industrial Electronics M6 connector Acceptance criteria.

7. Repeat steps 2-6 for each pair of terminals (one plug and one socket).

8. (optional) repeat steps 2-7, except replace the plug terminals with an applicable gauge. Use new socket terminals. can

Suitable gauges shall be made of polished steel with a nominal value less than 0.01 mm. The surface finish must be at least

076-0.305 microns (3-12 microinches). The polishing direction must be parallel to the length of the blade / plug pin. try

Another 10 socket terminal samples were tested to determine the force interaction between the polishing gauge and the actual sample.Industrial Electronics M6 connector


Industrial Electronics RF CABLE


Industrial Electronics RF CABLE Fully identify and number each tested terminal. A minimum of 20 samples (10 plugs and 10

Sockets). If the optional step 8 is to be used, a minimum of 10 socket terminal samples are required.

2. Fix each plug terminal and socketterminal to ensure their coaxiality during the test.

3. Engage the paired terminals at a uniform rate not exceeding 50 mm / min. The direction of the applied force shall be parallel to that of the terminal

Center line. In order to avoid side load and adverse factors on force measurement, ensure that the terminal coaxiality is from to

It's important.

4. Record the peak force required for the terminal to fully engage with the mating part and use this value to verify compliance with table 5.2.1.4

Acceptance criteria.

5. Separate the paired terminals at a uniform rate not exceeding 50 mm / min. The direction of the applied force shall be parallel to that of the terminal


6. Repeat steps 3 and 5 9 times and record the 10th separation force reading. Use this value to verify compliance with 5.2.1.4

Monday, July 20, 2020

Cameras Peripherals It is clearly identified in the drawing.


5.1.4.4 ergonomics level

The ergonomic test level of parts shall be in accordance with the requirements of SAE / uscar25. This level should be in the test plan and

It is clearly identified in the drawing.

Test end plates and direct connection components

It often happens that we only have a part of the connector, usually part of the socket, and it is directly connected with one

One end plate or socket for an electrical component or device. This creates special test problems. In order to be able to execute completely

For electrical connection test, we must be able to touch the terminals in the equipment or end plate. In these cases, great care must be taken to

Avoid leakage circuit in body applications. If the risk is unacceptable, or it is not possible to establish it necessary

For electrical connections, the tests that usually need to verify the integrity of the connection must be modified.

Sometimes, some other problems may occur due to the terminal in the equipment or terminal board or the length of the bus bar bus in the electrical performance test.

Cameras Peripherals M23 cable


Cameras Peripherals M23 cable 5.1.4 grade

5.1.4.3 vibration level

The tested parts need to be tested according to the following classification according to their installation position and environment;

V1: vibration diagram of parts installed in elastic parts of locomotive and not connected with engine shall meet vibration requirements according to 5.4.6.3e

5.4.6.4.

V2: the vibration diagram of the parts connected to the engine is shown in 5.4.6.3d, and the requirements shall meet 5.4.6.4.

V3: the vibration diagram of parts installed in severe vibration parts shall be in accordance with 5.8.2.3b and 5.8.2.3c, and the vibration requirements shall meet 5.4.6.4

Description in.Cameras Peripherals M23 cable.

Grade application type

V1 is mounted on elastic components that are not connected to the engine

V2 is installed on the components connected to the engine

V3 components installed in severe vibration environment

Figure: 5.1.4.3 vibration classification of parts Cameras Peripherals M23 cable.

Monday, July 13, 2020

Cameras Peripherals M5 cable


Cameras Peripherals M5 cable
The junction box on the traditional solar panel only has the function of connecting the panel and transmitting the current. However, in the 25 year long use of the solar photovoltaic system, it often encounters the influence of shielding factors such as chimney, tree shade, bird manure, black cloud, dust and so on, which greatly reduces the power generation efficiency and increases the fire risk. In serious cases, when 10% of the generating area of the photovoltaic system is blocked, 

the maximum power loss may be as high as 60% of the whole system; at the same time, even if there is no special factor, in the normal use environment, the solar power station will cause 9% to 11.5% of the total power loss due to various comprehensive factors, which is not only a major safety hazard for the photovoltaic system, but also makes the photovoltaic system The benefit of power generation is greatly reduced.Cameras Peripherals M5 cable

Cameras Peripherals M10 connector


Cameras Peripherals M10 connector 1. A kind of quick installation technology for instant use of butt insertion and quick tool removal. Through 180 degree inclined back buckle on both sides and chamfered pre guide hole, the product can use the inclined angle as the guide during butt insertion to achieve quick insertion action. The disassembly can be separated by 90 degree and 180 degree direct insertion of special tools

2. After the product is coupled, the direct distance between the external touch and the internal conductor is lengthened, which is 1.5 times of the safety distance of similar products in the same industry, thus increasing the rated voltage from 1000V to 1500V, or even higher Cameras Peripherals M10 connector.

3. A reliable structure technology of hydrolysis resistant material. The crystals of similar materials in the same industry are basically strip crystallized. The reaction of hydrolysis resistance of strip crystallized material is very sensitive, and its service life is greatly reduced when it operates in harsh environment. The updated material is branch network crystal structure, and its hydrolysis resistance has been improved unprecedentedly, which is more than 100% higher than the original hydrolysis resistance, Thus, the stability of its work and the life of its operation in harsh environment are improved, and the application product is upgraded to a new level.

Monday, July 6, 2020

Tools Machinery industrial M6 cable 1500V 200A

Tools Machinery industrial M6 cable
5.1.9 Considerations due to operating temperature
The installation shall not result in the maximum rated operating temperature of any
component being exceeded.
PV modules ratings are stated at standard test conditions (25 °C).
Under normal operating conditions, cell temperatures rise significantly above ambient. A Tools Machinery industrial M6 cable 1500V 200A
typical temperature rise of 25 °C is common with respect to the ambient temperature for
crystalline silicon PV modules under 1 000 W/m2 solar irradiance and with adequate
ventilation. The temperature rise can be considerably higher when irradiance levels are
greater than 1 000 W/m2 and when modules have poor ventilation.
The following main requirements on the PV array design derive from this operating
characteristic of PV modules.

Tools Machinery industrial M6 cable 1500V 200A

Tools Machinery industrial circular connector

Tools Machinery industrial circular connector series name :


Single core & multi-core connector
Hybrid HDTV connector
Plastic connector - P series
Plastic connector - R series
Coaxial / nim-camac connector
Coaxial triaxial hybrid connector
Fluid connector
Watertight air tight connector
High voltage connector
Thermocouple connector
Coaxial / triaxial (HDTV broadcast) connector
Anglissimo connector
High speed Ethernet connector
Remoting connector
Right angle connector
Halo led connector

Tools Machinery industrial circular connector