Industrial Electronics RF CABLE Fully identify and number each tested
terminal. A minimum of 20 samples (10 plugs and 10
Sockets). If the optional step 8 is to be
used, a minimum of 10 socket terminal samples are required.
2. Fix each plug terminal and socketterminal to ensure their coaxiality during the test.
3. Engage the paired terminals at a uniform
rate not exceeding 50 mm / min. The direction of the applied force shall be
parallel to that of the terminal
Center line. In order to avoid side load
and adverse factors on force measurement, ensure that the terminal coaxiality
is from to
It's important.
4. Record the peak force required for the
terminal to fully engage with the mating part and use this value to verify compliance
with table 5.2.1.4
Acceptance criteria.
5. Separate the paired terminals at a
uniform rate not exceeding 50 mm / min. The direction of the applied force
shall be parallel to that of the terminal
6. Repeat steps 3 and 5 9 times and record
the 10th separation force reading. Use this value to verify compliance with
5.2.1.4