Industrial Electronics RF CABLE Fully identify and number each tested terminal. A minimum of 20 samples (10 plugs and 10

Sockets). If the optional step 8 is to be used, a minimum of 10 socket terminal samples are required.

2. Fix each plug terminal and socketterminal to ensure their coaxiality during the test.

3. Engage the paired terminals at a uniform rate not exceeding 50 mm / min. The direction of the applied force shall be parallel to that of the terminal

Center line. In order to avoid side load and adverse factors on force measurement, ensure that the terminal coaxiality is from to

It's important.

4. Record the peak force required for the terminal to fully engage with the mating part and use this value to verify compliance with table 5.2.1.4

Acceptance criteria.

5. Separate the paired terminals at a uniform rate not exceeding 50 mm / min. The direction of the applied force shall be parallel to that of the terminal


6. Repeat steps 3 and 5 9 times and record the 10th separation force reading. Use this value to verify compliance with 5.2.1.4