Monday, December 28, 2020

camera module for The ambient light measured on the display surface M12 connector

 camera module for The ambient light measured on the display surface m12 connector (on standard diffuse reflectors) shall be 250 LX with a relative tolerance of ± 5%. If the display is set manually or automatically to night setting (e.g. triggered by headlamp switch or solar load sensor), the displayed information shall meet the requirements of 4.3.2 in night setting. If the driver can manually change the display setting to a higher contrast, the measurement can be made in the display setting. M9 connector.



Monday, December 21, 2020

Sensor Auto Focus Module The requirements of this subclause apply to the display

Sensor Auto Focus Module The requirements of this subclause apply to the display 


The requirements of this subclause apply to the display of the vehicle position on which it is installed, as seen at any point in the driver's eye in accordance with ISO 4513 (passenger cars only). medical connector


If the display is fixed to the vehicle, the requirements shall be observed from the last point of the independent eye ellipse. If the position of the display is adjustable, the display can be adjusted to find a position in which all relevant requirements are complied with at the same time. For direct sunlight conditions, the contrast requirement (see 4.3.2) can only be achieved in the direction of the critical specular reflection (CSL) (see Figure 1). M23 connector

Monday, December 14, 2020

The acceptance of the video display system project shall be completed

 the acceptance organization and responsibilities shall meet the following requirements:


1. The acceptance of the video display system project shall be completed by the construction unit, together with its relevant management departments, supervision, design, construction units and the third-party acceptance organization to establish a project acceptance team.



2. The acceptance organization shall make correct, fair and objective acceptance conclusions for the project according to the design specification, contract, relevant standards and formal design documents.


3 for the projects that have passed the acceptance or basically passed the acceptance, the acceptance organization shall cooperate with the construction unit to supervise and coordinate the implementation of the rectification measures written by the design and construction units according to the acceptance conclusions and approved by the construction units; for the projects that fail to pass the acceptance, the acceptance institutions shall clearly point out the problems and rectification requirements in the acceptance conclusions.

1080P USB2.0 Projector Camera Module Conditions and organization of project completion acceptance

 1080P USB2.0 Projector Camera Module Conditions and organization of project completion acceptance


7.3.1 the completion acceptance of video display system project shall meet the following conditions: M9 connector


1. Construction according to formal design documents.


2. The trial operation of the system meets the design requirements and is approved by the construction unit.


3. The preliminary inspection is qualified. M23 connector


7.3.2 before the formal acceptance of the project, the construction, design and construction units shall submit the following data to the project acceptance team:


1. Design specification.


2. Engineering contract.


3. Preliminary design demonstration opinions and detailed design opinions jointly signed by design, construction units and construction units.


4. Formal design documents, relevant drawings and design change notice.


5. System test run report.


6 project completion report.


7 system operation manual (including operation and routine maintenance instructions).


8 project completion accounting report.


9 project preliminary inspection report (including acceptance sheet of concealed works).


10 engineering inspection report.

Monday, December 7, 2020

M12 CONNECTOR The power on test shall meet the following requirements:

M12 CONNECTOR The power on test shall meet the following requirements:


1. Each video display unit, controller and other equipment shall be connected with power supply in different areas and shall not be powered on at the same time. The system joint commissioning should be carried out after the partition debugging is qualified.


2. In case of abnormal operation of the equipment, the power shall be cut off immediately, checked and repaired, and then the equipment shall be re debugged until the equipment operates normally, and the written record shall be made.


5.3.3 the installation of system control software shall meet the following requirements:


1. The operating system with good universality and compatibility should be adopted.


2. The software should be installed according to the requirements of the installation manual.


3. The basic configuration of application software should meet the requirements of display plane layout, display system wiring diagram, display screen size diagram, board bitmap, wiring list, etc.

The construction of usb camera control room shall meet the following requirements:

The construction of usb camera control room shall meet the following requirements:


1. The construction of control room shall meet the design requirements and comply with the relevant provisions of the current national standard "code for construction and acceptance of electronic information system room" (GB 50462 connector).


2. The installation of cabinet and rack shall comply with the relevant provisions of the current national standard "code for quality acceptance of intelligent building engineering" (GB 50339 M12 connector).


3. The termination of all kinds of jumpers and cables shall comply with the relevant provisions of the current national standard code for acceptance of generic cabling system engineering (GB 50312).


4. The installation of the console shall meet the following requirements:


1) The installation of the console shall meet the design requirements.


2) The console should be placed on the horizontal ground, and should be stable and firm.


3) The accessories shall be complete without damage; the table top shall be clean without scratches.


4) The wiring in the console should be arranged reasonably and orderly; the connector should be contacted reliably and installed firmly.


5. The grounding of control room shall meet the design requirements.


5.2.8 lightning protection and grounding of the system shall meet the design requirements, and shall comply with the relevant provisions of the current national standards "code for construction and acceptance of grounding device of electrical installation engineering" GB 50169 and "code for acceptance of construction quality of building electrical engineering" (GB 50303).

Monday, November 30, 2020

Engineering equipment and equipment shall meet the following requirements:

 Engineering equipment and equipment shall meet the following requirements:


1. For the mobilization of equipment and materials, table a.0.1-1 in Appendix A of this specification or the equipment and material mobilization inspection form provided by the supervision unit shall be filled in. The materials shall be counted and classified according to the construction equipment and material list.


2. During the open box inspection, the name, model, specification, quantity and place of origin of the equipment shall meet the design requirements, the appearance shall be intact, the technical data and accessories shall be complete, and the factory certificate shall be provided.


3. The function and performance of the equipment shall be checked by power on, and the test shall be carried out according to the corresponding current national product standards; if there is no national standard, it shall be carried out according to the contract provisions or design requirements; for the equipment without on-site inspection conditions, the factory test or the organization with inspection ability can be required to test, and the test report shall be issued.


4. The quality inspection contents of hardware equipment and materials shall include safety, reliability and electromagnetic compatibility.


5. The quality of software products shall be inspected according to the following contents:


1) For commercial software such as operating system, database management system, application system software, information security software and network management software, the use license and scope of use shall be checked.


2) The user application software, user configuration software and other application software compiled by the system Contractor shall not only carry out function test and system test, but also carry out capacity, reliability, safety, recoverability, compatibility, self diagnosis and other function tests as required. The software data such as program structure description, installation and debugging instructions, use and maintenance instructions shall be complete.


6 in addition to the provisions of article 1-5, the imported products shall also provide the certificate of origin and commodity inspection certificate; the product qualification certificate, inspection report, installation, use and maintenance instructions and other documents shall be in Chinese or attached with Chinese translation.

camera module M12 connector Construction of video display system

 camera module M12 connector Construction of video display system




5.1 construction preparation M12 connector Construction of video display system


5.1.1 the construction site shall meet the following requirements:


1. The construction object has basically met the entry conditions, and the operation site and safe power consumption should meet the construction requirements. The power supply and consumption at the construction site shall comply with the relevant provisions of the current national standard GB 50194.


2. The reserved pipes, holes, trunking and embedded parts shall meet the design requirements.


3. Various obstacles and sundries affecting the construction shall be removed.


5.1.2 construction preparation shall meet the following requirements:


1. Design documents, construction scheme, construction schedule and construction drawings shall be complete and have been jointly reviewed and approved.


2. The construction personnel shall be familiar with the construction drawings and all relevant data including engineering characteristics, construction scheme, process requirements, construction quality and acceptance standards.


3. The organization should be sound, the post responsibility should be clear, and the engineering guarantee measures should be formulated.


4 equipment, equipment, auxiliary materials, tools, machinery and communication tools shall meet the requirements of continuous construction and stage construction.

Monday, November 16, 2020

the classification of LED video display system shall meet the following requirements:

 Classification and classification of LED video display system


3.1.1 the classification of LED video display system shall meet the following requirements:


It can be divided into indoor display system and outdoor display system according to the use environment.


According to the display color, it can be divided into single primary color display system, double primary color display system and full color (red, green, blue three primary color) display system.


3.1.2 LED video display system can be divided into three levels: A, B and C. The performance and index of all levels of LED video display system shall meet the requirements of table 3.1.2.

AHD Camera Module from jsk technology china

 AHD Camera Module from jsk  technology china



Classification and classification of TV video display system


3.3.1 the classification of TV video display system shall meet the following requirements:


It can be divided into CRT, LCD, PDP and other display systems according to the types of display devices.


It can be divided into single screen TV display system and splicing display system according to the composition and quantity of display screen.




3.3.2 TV splicing video display system can be classified according to the provisions of article 3.2.2 of this specification.

Monday, September 7, 2020

13MP Camera Module cable assembly Tut tested terminal

13MP Camera Module cable assembly Tut tested terminal

 RH relative humidity




ROA temperature rise


TPA terminal position is ensured. See forward locking plus strength.



Uscar American Automotive Research Council. From Ford Motor Company, general motors company and DaimlerChrysler Co


An association of representatives of the division that conducts joint research to enhance the competitiveness of the U.S. automotive industry in non competitive regions


Research.


VD voltage drop

Baby Monitor Camera Module M12-connectors Design points

Baby Monitor Camera Module M12-connectors   Design points


For maximum rated current:




Note: the "maximum test power capacity" (section 5.3.3) detailed in this document is intended to establish test parameters. From here on


The parameters obtained are intended to limit the current in the 1008 hour current cycling test. The data collected during this test can also be


In order to compare the test results of different terminals under the same test specification. This test cannot Baby Monitor Camera Module M12-connectors Design points.


Determine the maximum current capacity of a specified size terminal. For a given application, in addition to the current load, other factors should be considered


Many factors. That can be passed through a terminal grip and


Interface over the life of the vehicle Baby Monitor Camera Module M12-connectors Design points.

Monday, August 31, 2020

720P USB2.0 Wide Angle Camera Module

 

720P USB2.0 Wide Angle Camera Module 


Retention:


Those acting on a single contact (terminal) do not cause them to come out of the correct position in the connector cavity


The maximum force of separation. There may be two different values for this force; one is that the relevant wedge (TPA) has been installed,


PLK, and so on), and the other is the value without these wedges installed.


Room temperature:


23°C ± 5°C


Separation force:


The force required to separate a pair of engaged contacts (terminals) or to separate a contact from a paired test instrument.

720P USB2.0 Wide Angle Camera Module



Circuit signal:


A circuit capable of providing a current of 5 A or less at all times


Soaking:


It refers to a period of time when the equipment under test is exposed to specified environmental conditions, such as temperature, humidity, current, etc.


The exposure process may be a preparation for another subsequent test, or it may be a specific test itself Part of.

Infrared Monitoring Camera Module M8 cable

Infrared Monitoring Camera Module M8 cable


 Maximum current capacity:


The maximum current carrying capacity refers to the terminal size, wire diameter and insulation class at room temperature determined according to section 5.3.3


The maximum current carrying capacity of a specific combination. The value must conform to the actual state of the specified application.


Mechanical auxiliary force:


Reduce the amount that operators use to fit the two halves of the connector or fit a connector to an end plate


The auxiliary means of force. Typical aids are the use of bolts, cams or levers.


Rated current:

Infrared Monitoring Camera Module M8 cable

According to wire size.


Power supply circuit: Infrared Monitoring Camera Module M8 cable


A circuit capable of continuously supplying more than 5A current for more than one minute.


Contact with heavy metals;


Where the terminals are connected to electricity, they need to be plated with gold, alloy, platinum or silver.Infrared Monitoring Camera Module M8 cable。

Monday, August 24, 2020

USB Camera M20 connector

 USB Camera M20 connector Remove or cut away to make room for slits, collets, and spindles. For clamping and fixing, if necessary, insert the pin


May be shortened. For a given structure, all pin positions should be tested, and in any case


The number of pins should not be less than 10.


1. By "dry as moulded parts", the samples were wet at 95-98% relative humidity and 40 ℃


Then the pull-out test was completed immediately.


2. If possible, the measurement should be carried out in both directions, for example, push the pin longitudinally through the connector, and then pull it out


It's like pulling the socket out of the end plate. In order to get the correct reading, according to personal design, "push" and "pull" should be the same


On the contrary. In a particular design, the connector tail may be properly loaded. For accurate results, the pressure and tension


It must be parallel to the center line of the pin. For pins with curved end plates in the vicinity of short plates, if necessary


The bent end plate can be cut. If it is necessary to cut the pin before applying the force to the test, we should first cut the pin


This will not affect the test results.


3. Fix the connector body in a suitable fixture.




The force tester applies an inclined pressure to the terminal pin. At the beginning of the pin in the plastic sheath or end plate attached


Note and record the forces as they begin to be replaced. Repeat for each pin position. When the connector sheath


When the inevitable damage affects the reading of the adjacent terminal hole, transfer it to an undamaged pin


Or use a new connector.


5. Repeat step 3 by reversing the direction of force according to the sample to be selected


USB Camera cable splitter -USB Camera cable splitter Retention of end plate pins

 USB Camera cable splitter Retention of end plate pins


5.7.1.1 purpose


The terminal pull-out test is used to determine the retention force of the socket terminal under the conditions of a specific pin or a molded end plate connector.


It can also be used to test the attachment of the plug pin when it is directly fixed or soldered to the circuit board. Appropriate pin protection


The holding force can ensure that the terminal will not be replaced by the normal insertion and pull-out force of the mating connector. These requirements can only be applied to


Finished devices, not for "in process" products, such as pin blocks or other semi assembled products. Units and / or connections


The provider needs to decide at which stage of the process these requirements will be tested and validated.


5.7.1.2 equipment


The insertion / pull-out force tester with peak number characteristics.


Suitable connector fixing device.


{collets, spindles or clamps holding terminals and / or pins in a longitudinal direction.


5.7.1.3 operation process USB Camera cable splitter Retention of end plate pins.


Note: the sample should be produced according to the intention of the product. For structures with very close pin arrangements, pins or terminals need to be selectively grounded

Monday, August 17, 2020

Low Power Camera Module M5 connector

Low Power Camera Module M5 connector If the sample has not been cycled through the connector and / or terminal of 5.1.7, it is completed.


3. Verify that each sample connector assembly meets the following acceptance criteria. Low power (weak current) circuit resistance test,


Chapter 5.3.1.4. If the test is performed separately. At least 10 pairs of terminals in the sample shall be measured at random.


4. Before the start of the test, the test fixture, system layout and test device must be approved by the authorized person.


5. Place the sample in the temperature chamber where the air flow to the sample will not be hindered and the samples will not touch each other


Put it on Low Power Camera Module M5 connector.


6. Refer to figure 5.1.4 to determine the temperature class that meets the requirements of the specified application of the connector system. Then set the temperature chamber at


At the lowest temperature of the grade. Stabilize the temperature of the temperature chamber before proceeding

Night Vision Monitoring Camera Module M9 connector

 Night Vision Monitoring Camera Module M9 connector 

Acceptance criteria


At the end of the test, verify that each pair of terminals and each sample connector assembly comply with 5.1.9.4 (continuous monitoring) and


Face acceptance criteria.


A. First, small power (weak current) circuit resistance test, chapter 5.3.1.4.


B. Second, voltage drop test, chapter 5.3.2.4.M9 connector 


Note: if the sample is to be further tested (e.g. as part of the test sequence listed in section 5.9.6)


The following steps should be postponed until the end of the sequence.


With the help of a 10x magnifying glass, do not see anything on the connector assembly that will affect the assembly and function of the connector or seriously degrade it


Defects such as damage, cracking and deformation of low appearance quality.


Assemble at least 10 pairs of fully engaged connectors (at least 10 plugs and 10 sockets) as specified in section 5.1.6


Connector half). Use any conductor size and insulation type applicable. Assembly must include all applicable wedges


(TPAs, PLRS, etc.), seals, etc. Number each mating connector.

Monday, August 10, 2020

Medical appliances M30 connector Force from bulk (open) position to self-locking position

 Medical appliances M30 connector :

B. Force from bulk (open) position to self-locking position

 

1. Use the connector without control lever to put the control rod or sliding vane in bulk position.

 

2. Force tester, gradually apply a force of 30n in one direction to assemble the control rod or sliding vane to the self-locking position

 

3. Verify whether the acceptance criteria of 5.4.3.4-3 are met.

 

C. Lever impulse / removal force

 

1. Test the force required to move the connector from the pre activated state to the fully used state and close the lever. It should be as much as possible

 

The orthogonal force can be applied close to the contact surface of the control rod or sliding plate.

 

2. For the connector with secondary self-locking structure, maintain this feature and gradually apply a 60N force at its release position.

 

3. If applicable, release all existing release mechanisms and record the amount required to move the lever from the locked position to the free position Force.

Medical appliances M6 Connector to connector fit / release force (connector with mechanical assistance)

 Medical appliances M6 connector :

Connector to connector fit / release force (connector with mechanical assistance)

 

5.4.3.1 purpose

 

This test includes the pulling and pulling force of the connector with self-locking structure such as control rod or locking plate. Ergonomics in uscar-25

 

The guidelines should be applied as a long-term reference.

 

5.4.3.2 equipment

 

? force tester

 

The fixture for fixing the connector

 

5.4.3.2.1 sample

 

Sufficient plug ends shall be prepared in accordance with section 5.1.6 (preparation of terminal samples) using suitable conductor size and insulation type

 

Sub and socket terminals to assemble connectors. Three tests a, B and C were carried out.

 

Prepare connector samples, including accessories such as wires, terminals and secondary locks, according to the design specification and product use intention

 

And so on. In each section below, prepare at least 10 sets of samples. Samples may be reused.

 

Test D; prepare plug terminal and socket sheath for assembly test.

 

Engagement force to preassembled position Medical appliances M6 connector .

 

1. Force tester to engage each connector to the preassembled position.

 

2. Reverse the direction and record the force required to move the connector from the pre installed position to the UN seat position.

 

3. Verify whether the acceptance criteria of 5.4.3.4-1 and 5.4.3.4-2 are met.

Monday, August 3, 2020

Industrial Electronics M30 cable


Industrial Electronics M30 cable Make a suitable mark on the terminal so that the person performing the test can make the only correct pair for the terminal, and

The test terminals to be engaged are inserted to the correct depth. It is not allowed to mark with scratches or other pollutants

Or change the strength or conductivity of the plug terminal or interface. Do not use the sheath of the connector, i.e Industrial Electronics M30 cable 。

Make it unclosed to control the insertion depth of the terminal, because the sheath will change the heat dissipation state during the test. such

Doing this will reduce the repeatability of the test and invalidate the comparative data collected for the various terminals.



Industrial Electronics M14 cable


Industrial Electronics M14 cable Prepare 20 terminal samples (at least 10 plug terminals and 10 socket terminals) according to the terminal sample preparation in section 5.1.6

The maximum size conductor and insulation thickness suitable for the tested terminal shall be used.

2. If the sample has not been cycled for connectors and / or terminals in 5.1.7, complete it.

3. For the purpose of this test, the plug terminal must be inserted into the socket terminal at a precise depth. The standard operation method is: Press

According to figure 5.3.1.4., in the worstcase, the rear contact point of the socket terminal and the

There must be at least 1 mm over insertion between all guide cones. As shown in figure 5.3.1.4. This size is authorized by

It is calculated based on the terminal diagram, taking into account the worst-case tolerance. Must be in each plug

Monday, July 27, 2020

Industrial Electronics M6 connector


Industrial Electronics M6 connector Acceptance criteria.

7. Repeat steps 2-6 for each pair of terminals (one plug and one socket).

8. (optional) repeat steps 2-7, except replace the plug terminals with an applicable gauge. Use new socket terminals. can

Suitable gauges shall be made of polished steel with a nominal value less than 0.01 mm. The surface finish must be at least

076-0.305 microns (3-12 microinches). The polishing direction must be parallel to the length of the blade / plug pin. try

Another 10 socket terminal samples were tested to determine the force interaction between the polishing gauge and the actual sample.Industrial Electronics M6 connector


Industrial Electronics RF CABLE


Industrial Electronics RF CABLE Fully identify and number each tested terminal. A minimum of 20 samples (10 plugs and 10

Sockets). If the optional step 8 is to be used, a minimum of 10 socket terminal samples are required.

2. Fix each plug terminal and socketterminal to ensure their coaxiality during the test.

3. Engage the paired terminals at a uniform rate not exceeding 50 mm / min. The direction of the applied force shall be parallel to that of the terminal

Center line. In order to avoid side load and adverse factors on force measurement, ensure that the terminal coaxiality is from to

It's important.

4. Record the peak force required for the terminal to fully engage with the mating part and use this value to verify compliance with table 5.2.1.4

Acceptance criteria.

5. Separate the paired terminals at a uniform rate not exceeding 50 mm / min. The direction of the applied force shall be parallel to that of the terminal


6. Repeat steps 3 and 5 9 times and record the 10th separation force reading. Use this value to verify compliance with 5.2.1.4

Monday, July 20, 2020

Cameras Peripherals It is clearly identified in the drawing.


5.1.4.4 ergonomics level

The ergonomic test level of parts shall be in accordance with the requirements of SAE / uscar25. This level should be in the test plan and

It is clearly identified in the drawing.

Test end plates and direct connection components

It often happens that we only have a part of the connector, usually part of the socket, and it is directly connected with one

One end plate or socket for an electrical component or device. This creates special test problems. In order to be able to execute completely

For electrical connection test, we must be able to touch the terminals in the equipment or end plate. In these cases, great care must be taken to

Avoid leakage circuit in body applications. If the risk is unacceptable, or it is not possible to establish it necessary

For electrical connections, the tests that usually need to verify the integrity of the connection must be modified.

Sometimes, some other problems may occur due to the terminal in the equipment or terminal board or the length of the bus bar bus in the electrical performance test.

Cameras Peripherals M23 cable


Cameras Peripherals M23 cable 5.1.4 grade

5.1.4.3 vibration level

The tested parts need to be tested according to the following classification according to their installation position and environment;

V1: vibration diagram of parts installed in elastic parts of locomotive and not connected with engine shall meet vibration requirements according to 5.4.6.3e

5.4.6.4.

V2: the vibration diagram of the parts connected to the engine is shown in 5.4.6.3d, and the requirements shall meet 5.4.6.4.

V3: the vibration diagram of parts installed in severe vibration parts shall be in accordance with 5.8.2.3b and 5.8.2.3c, and the vibration requirements shall meet 5.4.6.4

Description in.Cameras Peripherals M23 cable.

Grade application type

V1 is mounted on elastic components that are not connected to the engine

V2 is installed on the components connected to the engine

V3 components installed in severe vibration environment

Figure: 5.1.4.3 vibration classification of parts Cameras Peripherals M23 cable.

Monday, July 13, 2020

Cameras Peripherals M5 cable


Cameras Peripherals M5 cable
The junction box on the traditional solar panel only has the function of connecting the panel and transmitting the current. However, in the 25 year long use of the solar photovoltaic system, it often encounters the influence of shielding factors such as chimney, tree shade, bird manure, black cloud, dust and so on, which greatly reduces the power generation efficiency and increases the fire risk. In serious cases, when 10% of the generating area of the photovoltaic system is blocked, 

the maximum power loss may be as high as 60% of the whole system; at the same time, even if there is no special factor, in the normal use environment, the solar power station will cause 9% to 11.5% of the total power loss due to various comprehensive factors, which is not only a major safety hazard for the photovoltaic system, but also makes the photovoltaic system The benefit of power generation is greatly reduced.Cameras Peripherals M5 cable

Cameras Peripherals M10 connector


Cameras Peripherals M10 connector 1. A kind of quick installation technology for instant use of butt insertion and quick tool removal. Through 180 degree inclined back buckle on both sides and chamfered pre guide hole, the product can use the inclined angle as the guide during butt insertion to achieve quick insertion action. The disassembly can be separated by 90 degree and 180 degree direct insertion of special tools

2. After the product is coupled, the direct distance between the external touch and the internal conductor is lengthened, which is 1.5 times of the safety distance of similar products in the same industry, thus increasing the rated voltage from 1000V to 1500V, or even higher Cameras Peripherals M10 connector.

3. A reliable structure technology of hydrolysis resistant material. The crystals of similar materials in the same industry are basically strip crystallized. The reaction of hydrolysis resistance of strip crystallized material is very sensitive, and its service life is greatly reduced when it operates in harsh environment. The updated material is branch network crystal structure, and its hydrolysis resistance has been improved unprecedentedly, which is more than 100% higher than the original hydrolysis resistance, Thus, the stability of its work and the life of its operation in harsh environment are improved, and the application product is upgraded to a new level.

Monday, July 6, 2020

Tools Machinery industrial M6 cable 1500V 200A

Tools Machinery industrial M6 cable
5.1.9 Considerations due to operating temperature
The installation shall not result in the maximum rated operating temperature of any
component being exceeded.
PV modules ratings are stated at standard test conditions (25 °C).
Under normal operating conditions, cell temperatures rise significantly above ambient. A Tools Machinery industrial M6 cable 1500V 200A
typical temperature rise of 25 °C is common with respect to the ambient temperature for
crystalline silicon PV modules under 1 000 W/m2 solar irradiance and with adequate
ventilation. The temperature rise can be considerably higher when irradiance levels are
greater than 1 000 W/m2 and when modules have poor ventilation.
The following main requirements on the PV array design derive from this operating
characteristic of PV modules.

Tools Machinery industrial M6 cable 1500V 200A

Tools Machinery industrial circular connector

Tools Machinery industrial circular connector series name :


Single core & multi-core connector
Hybrid HDTV connector
Plastic connector - P series
Plastic connector - R series
Coaxial / nim-camac connector
Coaxial triaxial hybrid connector
Fluid connector
Watertight air tight connector
High voltage connector
Thermocouple connector
Coaxial / triaxial (HDTV broadcast) connector
Anglissimo connector
High speed Ethernet connector
Remoting connector
Right angle connector
Halo led connector

Tools Machinery industrial circular connector


Monday, June 29, 2020

Tools Machinery industrial RFI / EMI shielding performance B Series E series K series s series

Tools Machinery industrial RFI / EMI shielding performance B Series E series K series s series

Tools Machinery industrial RFI / EMI shielding performance B Series E series K series s series Analyzer, process controller, ul61010a are reliably connected for data acquisition. Sealing characteristics can be used in humid environment. Flexible seal tube and seal ring can be used in harsh environment. Stainless steel material can be sterilized at high temperature and has a long service life. B-series E-Series K-series S-Series dental instruments are equipped with a mixed needle core configuration, which can choose jet / air flow, optical fiber (lighting - there is no hot light ball in the patient's body), B-series K-series Redel P-Series R-Series disposable disposable equipment (sensors, catheters) are reliably connected in a sensitive environment, and plastic materials are close to medical equipment materials. B-series Redel P-Series S-Series electrical and scientific equipment mixed signal input, excellent RFI / EMI shielding performance. B Series E series K series s series pacemakers and hearing aids.

Tools Machinery industrial 5G M9 connector


Tools Machinery industrial 5G M9 connector The status quo of 5g and the launch of the new 5g mobile standard in the application field are in preparation. The initial requirements of the standard have been identified, and now its detailed definition and subsequent implementation are in the process of being initiated. The successor of current mobile standard LTE (4G) aims to improve latency, provide higher bandwidth, and create a foundation for new possible applications due to its enhanced performance. There will be several development levels or "releases.". 5g standardization starts from release 15
(R15), released in June 2019, mainly determines the current specifications of 5g mobile devices, including CPE and mobile phones. This version sets two frequency ranges: FR1 (frequency range 1) andTools Machinery industrial 5G M9 connector .
Previously below 6GHz, now (per R16) below 7.125ghz; and FR2, which has a frequency band below 52.6ghz, including part of the so-called mmwave spectrum.


Tools Machinery industrial 5G M9 connector

Monday, June 22, 2020

Cameras Peripherals M14 cable

Cameras Peripherals M14 cable
Most vandalism switches are designed with round buttons. The switch frame and actuator are made of stainless steel with high mechanical strength and chemical resistance. The actuator is the most frequently used part of the switch, and its shape design usually reduces the risk of potential saboteurs misoperation and damage.Cameras Peripherals M14 cable .

In a small design, the actuator helps to limit the distance between the switch and the panel, thereby minimizing damage caused by a screwdriver or other thin tool, while simplifying operation. These switches, also known as vandalism switches, are connected to the panel using the pre installation technology, further ensuring that the switch has a smooth outer contour by safely hiding the retaining nuts (called locknuts) behind the panel.Cameras Peripherals M14 cable .
Cameras Peripherals M14 cable

Cameras Peripherals M8 cable Switch

Cameras Peripherals M8 cable Switch
Switch is one of the most powerful components in electronic products. The function of the switch is different from other components and it is an important interface between the operator and the machine. Among all kinds of switches, one must be stronger than most, that is, vandalism proof switch. No matter what application, this type of switch must provide powerful function, reliable performance and solid protection, and also be easy to install and use. Cameras Peripherals M8 cable .Most importantly, these switches must provide reliable protection against malicious tampering and damage to equipment.

Cameras Peripherals M8 cable Switch

Sunday, June 14, 2020

Low voltage apparatus M30 connector

Low voltage apparatus M30 connector

Low voltage apparatus M30 connector


The industrial batteries of the automobile electric vehicles are integrated together by the battery pack of the battery box, and the batteries of the low-power lithium battery are integrated together. After the copper bar and aluminum bar are fused and welded, they are connected and integrated together. When the bus bar is pressed on the main line, the output of the main line will become a state of high current and low voltage. This place will apply the plug and socket of the battery pack. When the bus bar is converged, the aluminum bar circuit g of the copper bar is mainly used GB7000 connector to complete the connection.
Li battery connecting line, socket with cover, Li battery charging XLR plug, t + XLR plug, total length about 80cm, Li battery electric vehicle charging interface, 36v48v charger output line plug, dc2.1 video head, Canon head, the same model, dc2.1 plug, 10 DC card socket, Li battery battery vehicle charging pile, conversion head, three hole XLR socket, three vertical pin socket, AC to XLR head Three hole XLR socket to three vertical socket electric scooter balance car Harley car charging port aviation empty XLR socket three hole plug small plug.

Low voltage apparatus M16 connector

Low voltage apparatus M16 connector 

Main products: Automobile Electric vehicle aviation Motorcycle E-bike Plug and socket of lithium battery pack XLR head XLR base copper bar aluminum bar circuit connector, GB7000 connector, GB4706connector, output line of lithium battery electric vehicle charger, charging round head port, male and female socket, dc2.5 (charger output line), output line of lithium battery electric vehicle charger, XLR plug and socket, three core charging port, lotus head, aviation head, such as dc2.1 female socket, socket panel, 16A Three hole XLR charging port with cover,
Low voltage apparatus M16 connector .


Sunday, June 7, 2020

weak current equipment M16 cable M40 connector

weak current equipment M16 cable


4 What do you do? It is better for the inventor to summarize what his overall technical solutions are and what technical features are included in these technical solutions. If the technical solution is hardware, what components does it include? What are the functions of the components? How are they connected? If the technical solution is software or method, what steps does it include? What is the function of each step? What is the order between the steps?

5 What are the benefits?

6 Specific implementation (how you do it). This part is a further refinement of the general technical scheme. It is better for the inventor to give several examples to elaborate how the general technical scheme is implemented. The description of this part is best combined with the attached drawings. For example, if the technical solution of the invention is hardware, the block diagram and structure diagram shall be given as detailed as possible, and if the technical solution of the invention is software or method, the flow diagram shall be given as detailed as possible.

weak current equipment M16 cable M40 connector


weak current equipment M12 cable


weak current equipment M12 cable The technical disclosure shall be able to reflect the following five aspects:

1 What are you going to do? What is the inventor's invention? What is the name of invention? What is the technical field of invention and creation?

2 What do others do? In other words, what is the background technology? What is the basis of invention? At the same time of introducing the current situation of the related technology field, the inventor should analyze what kind of shortcomings exist in the background technology to make the inventor continue to research, what are the reasons for the research, and what are the difficulties encountered? weak current equipment M12 cable.

3 Why do you do it? Let's talk about why do you do it when similar technologies already exist? Specifically, it refers to the problems existing in the prior art to be solved by the invention and creation. That is to say, in the view of the inventor, what are the deficiencies or defects of the technical scheme or means introduced in the above background technology, so that the inventor can continue to study and finally make an invention on the basis of the above background technology?
weak current equipment M12 cable


Monday, June 1, 2020

weak current equipment M14 connector

weak current equipment M14 connector

Shrinkage cavity: the irregular shape and rough surface hole caused by insufficient internal compensation during the condensation process of die casting.

Under casting: filling incomplete parts in the process of die casting.
weak current equipment M14 connector


Crack: the alloy matrix is damaged or broken, forming a long and thin gap, which is irregular and linear. There are two kinds of cracks: penetrating and non penetrating

There is a trend of development under the influence of external forces. Cracks can be divided into cold cracks and hot cracks. The main difference is the cold crack casting

The metal at the crack is not oxidized while the hot crack is oxidized.

Wrong mold: when the mold is closed, the relative position of the moving part (including the movable part of the mold) and the fixed mold are not accurate, resulting in the dislocation (relative displacement) trace of the casting shape. In general, it is called wrong thread.

Non ferrous spot: a spot on the surface of a casting that is different from the color of the base metal. ,

Pockmarked surface: in the process of filling the cavity with liquid metal, fine pockmarks with linear distribution (mostly dense) are formed on the surface of the casting

The area formed.

Ejector mark: the mark of protrusion or depression left after the surface of the die-casting is in contact with the inlaid or movable part of the die, ejector, etc.

Inclusions: metal or non-metal impurities mixed into the die casting. After the casting is processed, the size of the irregular shape is shown here,

The spots or holes with different colors and brightness are often partially or completely filled with impurities.

Loose: the small holes on the die casting caused by aggregation or dispersion cause local non dense structure.

Flash: sheet metal on the edge of the parting surface (or moving part) of a die casting.

Fleshy: the same part of the surface of the die-casting repeatedly appears redundant protruding parts of the same shape.

Deformation: the overall deformation of the die-casting parts whose geometry does not conform to the drawing.

Mechanical damage: the scar on the surface of die casting caused by mechanical impact.

Brittleness: the grain of casting base metal is too coarse or small, which makes the casting easy to break or break.

Leakage: the die casting has water leakage, air leakage or water seepage after test.

weak current equipment M8 connector M9 connector

weak current equipment M8 connector

Air hole (sand hole): the hole with regular shape and smooth surface formed by the gas involved in the die casting.M9 connector

Flow mark: on the surface of the die casting, there is a line consistent with the flow direction of the liquid metal, which can be felt by hand to be locally depressed, which is a defect

There is no possibility of development.M10 connector

vacuum bipolar RF socket


Cold insulation: Joint mark caused by butt joint or non fusion of metal flow. Its intersection edge is smooth, with penetration and non penetration

Species have a trend of continuous development under the action of external forces.

Scratch: there is a certain depth of line like damage trace on the surface of the casting along the direction of casting, which is a stack of scars in serious cases.

Dent: a concave part on the smooth surface of a die casting.

Adherent trace: the trace left on the die casting due to the falling off of sheet metal or coating accumulation, if the sheet metal does not fall off,

If the local fusion has obvious metal layer on the casting, it is delamination.

Net burr: a net protrusion (or concave pattern) on the surface of the casting caused by the cracks on the surface of the mold cavity.

Bubble: the bubble formed by the gas bulging in the subcutaneous pores of the die casting.
weak current equipment M8 connector M9 connector

Monday, May 25, 2020

Industrial robot M10 connector


Industrial robot M10 connector Speed of medical connector
In order to ensure the success of this minimally invasive surgery, previous surgeons used to monitor and promote these types of operations by transmitting real-time images from patients' laparoscopic cameras. The modern connector technology allows these large amounts of data to be transmitted at high speed and has high integrity, which greatly promotes the success of these operations.


Industrial robot M10 connector

Industrial robot M10 connector

Industrial robot M16 connector medical connector Amphenel AISG C091 connector assembly

Industrial robot M16 connector medical connector

Components of medical connector
Industrial robot M16 connector medical connector Amphenel AISG C091 connector assemblySimilar to smart phones, medical devices have shape requirements. Thanks to recent medical advances, surgeons can perform certain operations. Some medical devices allow surgeons to perform their complex operations, such as bypass surgery, by creating a small incision and inserting a laparoscopic camera. The success of these types of operations also depends on the complex components within the medical device, such as connectors, and the ability of the operating system to perform and optimize the function of the device.


Industrial robot M16 connector medical connector Amphenel AISG C091 connector assembly

Monday, May 18, 2020

Communication Equipment M20 cable Insertion force

Communication Equipment M20 cable Insertion force

 Communication Equipment M20 cable Insertion force


a. Place the two matching electronic connectors in the initial position of the mechanical assembly, and the reading of the dynamometer and the torque meter is zero.

b. Fully insert (match) the connector according to the force rate specified in the specification, and record the peak value of insertion force.

3. Pull out force

Pull out the connector completely according to the force rate specified in the specification, and record the peak pulling force.

4. Details

When testing according to specifications, the following details will be explained:

(a) Number of samples tested

(b) Insertion force and pull-out force

(c) Plugging rate

(d) Possible insertion depth.

5. References

The data form includes:

(a) Test title

(b) Sample description including installation tools

(c) Test instruments used

(d) Test steps

(e) Assessment and observation

(f) Test date and operator name.

Communication Equipment M16 cable

Communication Equipment M16 cable Test instruments include:

1. Mounting fixture that allows the sample to be installed in a normal manner.

2. During the test, the force gauge or force distance gauge shall be placed in the proper position of the connector so that the reading pointer is in the middle of the gauge, so that the operation gauge can be accurate to ± 2%.

3. According to the requirements, the auxiliary measuring instrument shall match the test sample and be accompanied with the force measuring table and torque table (axial pressure, etc.).

b) . test steps

1. Unless otherwise specified, the sample shall be installed as normal.
Communication Equipment M16 cable

Communication Equipment M10 cable

Communication Equipment M10 cable Test method ා 13A -- Test Method for plug force of electronic connector

(from EIA recommendation No. 1653. Organized by EIA working group p-5.12.)

Note: tp-13a was previously published as tp-13 in EIA recommendation rs-364-3.

1. Purpose:

The purpose of this test is to introduce a standard method for determining the insertion force required for an electronic connector or its protective cover.

2. Sample preparation

The test sample consists of a plug and a contact socket. Unless otherwise specified, the sample shall consist of all available hardware including edges, hoods, clamps, screws, guides or sockets. Unless otherwise specified in the specification, the sample does not need to be lubricated or cleaned by any means.

3. Test method

a) . test instruments

Monday, May 11, 2020

Communication Equipment M12 x-code 8pins M30 connector

Communication Equipment  M12 x-code 8pins
Ximeconn has newly launched M12 x-code connector series, which conforms to iec61076-2-109 standard, and has cross shielding design to eliminate interference and unnecessary signals in signal transmission. Moreover, this connector meets the ultra-high requirements of signal transmission integrity from structural design and experimental test. The M12 x-code connector with 360 ° all-round shielding and cat 6A wire can achieve 10Gbps Ethernet transmission speed. Compared with the traditional RJ45 series or M128 core A-code connector (only supporting 10 / 100Mbps Ethernet transmission speed), there is no doubt that M12 x-code connector with more efficient transmission speed has more advantages.

M12 x-code connector is the most ideal solution for high-speed Ethernet transmission in wireless, camera, vision system and other harsh environments, because it not only has high-speed and robust data transmission characteristics, but also meets IP67 waterproof design.

Communication Equipment  M12 x-code 8pins 

Communication Equipment  M12 x-code 8pins 

Communication Equipment M16 connector

Communication Equipment M16 connector 
These are another embodiment of the struggle oriented. This care and consideration are not only "cool" on the body, but also warm in the heart. Everyone is happy to be able to work in such a company. Look at our production workshop, clean and bright floor, orderly U-shaped assembly line, such a spotless working environment, people feel more comfortable. Yes, we always pay attention to employees' feelings and create a good working environment for them. We have been improving



We believe that a good working environment can make employees happy physically and mentally, and can produce high-quality products. The level of enterprise management can be seen from the status of employees and the appearance of the factory.


Communication Equipment M12 connector

Communication Equipment M12 connector Ximeconn provides customers with male connector and panel type female connector with wire wrapping glue. The glue wrapping scheme can not only save the time of clients, but also provide a complete set of wire harness processing services. The PCB board inserting mode of panel type rear mount effectively saves the welding process. What's more amazing is that the x-code series has blind plug-in function, making it easier for customers to use.



Ximeconn will continue to launch a wide range of accessories series to expand the M12 x-code family, to meet or even exceed customers' changing needs.
 
Communication Equipment M12 connector